Problem |
Possible Cause |
Possible Solution |
Notes |
|
No gas flow to pilot |
No gas from meter |
Turned off at meter |
Call gas provider |
|
No gas flow to pilot |
No gas from regulator |
Debris in regulator |
Remove and inspect |
|
No gas flow to pilot |
Faulty regulator |
Replace regulator |
Cannot rebuild unless you are certified |
|
No gas flow to pilot |
Crimped pilot tube |
Repair or replace tube |
|
|
No gas flow to pilot |
Leak in pilot tube |
Replace tube |
|
|
No pilot flame |
No gas flow from regulator |
See above information |
|
|
No pilot flame |
Defective thermocouple |
Replace thermocouple |
Residential Type |
|
No pilot flame |
Defective thermopile |
Replace thermopile |
Commercial Type |
|
No pilot flame |
Air in gas piping |
Purge air from piping |
|
|
No pilot flame |
Defective regulator |
Replace regulator |
Cannot rebuild unless you are certified |
|
No gas flow to burner |
Defective regulator |
Replace regulator |
Cannot rebuild unless you are certified |
|
No gas flow to burner |
Crimped burner tube |
Repair or replace tube |
|
|
No gas flow to burner |
Blockage in burner tube |
Remove and clean |
|
|
No gas flow to burner |
Water is too hot |
Run water to cool tank |
Push reset button
Commercial Type |
|
No gas flow to burner |
Defective high limit device |
Replace device |
Commercial Type |
|
Relief valve leaking |
Water is too hot |
Run water to cool tank |
Lower thermostat setting |
|
Relief valve leaking |
Defective relief valve |
Replace relief valve |
Same rating |
|
Relief valve leaking |
Excessive pressure |
Install expansion tank |
Size per heater |
|
Relief valve leaking |
Excessive pressure |
Check PRV to system |
Maximum is 80 PSI
(NC Code, Check Yours) |
|
Low water temperature |
Thermostat set too low |
Adjust temperature |
|
|
Low water temperature |
Dip tube failure |
Inspect and replace |
Top fed type heater |
|
Low water temperature |
Defective thermostat |
Replace thermostat |
|
|
Slow recovery |
Sediment in tank |
Drain and flush tank |
Residential type |
|
Slow recovery |
Dirty burner assembly |
Clean burner |
|
|
Slow recovery |
Poor flame |
Adjust burner air |
|
|
Slow recovery |
Poor flame |
Need combustion air |
Install air supply duct |
|
Not enough hot water |
Improper size heater |
Calculate demand |
Size per BTU required |
|
Not enough hot water |
See above information |
See above information |
Recovery / Temperature |
|
Popping / banging noise |
Calcium build up |
Drain and flush tank |
Noise while heating |
|
Popping / banging noise |
Sediment build up |
Drain and flush tank |
Noise while heating |
|
Banging noise |
Check valve slamming |
Install shock absorber |
Noise after water flow |
|
Banging noise |
Solenoid to equipment somewhere in system |
Install shock absorber |
At equipment location |
|
Fume odor |
Poor draft on flue system |
Flue pipe installation |
Check horizontal pipe |
|
Fume odor |
Poor draft on flue system |
Termination location |
Check roof area |
|
Gas odor |
Leak on piping system |
Soap all piping joints |
Repair Leaks |
|
Soot build up |
Poor draft on flue system |
See above information |
Fume odor |
|
Soot build up |
Poor draft on flue system |
Install draft fan |
May void warranty |
|
Soot build up |
Poor combustion air |
Install air supply ducts |
High and low air |
|
Soot build up |
Poor burner flame |
Clean and adjust |
See above information |
|
Flame back flash |
Negative air pressure |
Isolate heater air |
Equalize with outside air |
|
Flame back flash |
Restaurant draft hood |
Isolate heater air |
Check louver door |